• Specification: Extraction & condensing, Inlet pressure: 104 bar, Output: 215MW, Extractions: MP2: 22 bar, MP1: 10 bar, LP: 4.5 bar, Feed Water: 0.4 bar, Minimum load: No extractions, Only bleeds, Steam flow: 45 kg/s, Maximum load: Steam flow: 270 kg/s. • Generator: 250 MVA, Air to Water Cooled, 18 kV, 8019 A, 50 Hz, 3000 rpm • Condenser: Average: 17 ºC, Min: 15 ºC, Max: 25 ºC. See attachment for inventory list of all items included and packaging details • Storage Conditions: Delivered 2009 and unused, currently stored indoors and secured, Turbine & Generator completely sealed, silica gel is inserted in the Turbine & Generator and regularly replaced. Equipped with electronic monitoring sensors for humidity and temperature with criteria from Toshiba for storage.
|
|
|